2.5 Operating Example

2.5.1
Operation via Control terminal + Keypad
Setting:
DRV-03 [Drive Mode (Run/Stop method)] = 1 (Fx/Rx-1)
DRV-04 [Frequency Mode (Freq. setting method)] = 0 (Keypad-1)
l
With above setting, Freq setting via terminal & Run/Stop via Keypad disabled
1.
Check the LCD display when Power ON. Otherwise, change the setting indicated above.
DRV▶T/K
00
STP
2.
Turn the FX (or RX) terminal ON. Then FWD (or REV) LED will be lit.
DRV▶T/K
00
FWD
3.
When setting the Ref. Freq to 60 Hz using PROG/ENT/SHIFT , ? keys, motor will rotate at 60Hz.
FWD (or REV) LED will be flickering during Acceleration/ Deceleration.
DRV▶ Cmd. freq
00
0.00Hz
4.
Turn Fx (or Rx) terminal Off. Then Stop LED will be lit.
DRV▶T/K
00
STP 60.00Hz
Note) To enable Run/Stop via keypad & Freq setting via control terminal...
Setting: DRV-03 [Drive Mode (Run/Stop method)] = 0 (Keypad)
DRV-04 [Frequency Mode (Freq. setting method)] = 2 (V1)