DRV-02: Deceleration Time

DRV? Dec. time
02
30.0 sec
Factory Default:
30.0 sec
The inverter targets the FU2-70 when accelerating or
decelerating. When the FU2-70 is set to " Maximum
Frequency" , the acceleration time is the time taken by
the motor to reach FU1-20 from 0 Hz. The deceleration
time is the time taken by the motor to reach 0 Hz from
FU1-20 [Maximum Frequency].
When the FU2-70 is set to ' Delta Frequency' , the
acceleration and deceleration time is the time taken to
reach a targeted frequency (instead the maximum
frequency) from a frequency.
The acceleration and deceleration time can be changed
to a preset transient time via multi-function inputs. By
setting the multi-function inputs (P1, P2, P3) to ' XCEL-L' ,
' XCEL-M' , ' XCEL-H' respectively, the Accel and Decel
time set in I/O-25 to I/O-38 are applied according to the
binary inputs of the P1, P2, P3.
Output Frequency
Max. Freq.
Acc. time
Related Functions:
FU1-20 [Max freq]
FU2-70 [Reference freq. for Accel/Decel]
FU2-71 [Accel/Decel time scale]
I/O-12 to I/O-14 [Multi- function input
terminal P1, P2, P3]
I/O-25 to I/O-38 [Acc/Dec time for step
frequency]
n
FU2-70: Selects the frequency to be targeted for acceleration
and deceleration. [Max Freq, Delta Freq]
n
FU2-71: Selects the time scale. [0.01, 0.2, 1]
n
I/O-12 to I/O-14: Sets the terminal function of P1, P2, P3
terminal inputs.
n
I/O-25 to I/O-38: Presets the Accel/Decel time activated via
multifunction inputs (P1, P2, P3)
I/O-12 to I/O-14: Sets the terminal function of P1,
☞ Note:
P2, P3 terminal inputs.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
02
30.0
30.0
Time
Dec. time
81
Chapter 6 - Parameter Description [DRV]
LCD
Code
Description
display
DRV-
Acc time
Acc time 0
01
DRV-
Dec time
Dec time 0
02
I/O-25
ACC-1
Acc time 1
I/O-26
DEC-1
Dec time 1
I/O-27
ACC-2
Acc time 2
I/O-28
DEC-2
Dec time 2
I/O-29
ACC-3
Acc time 3
I/O-30
DEC-3
Dec time 3
I/O-31
ACC-4
Acc time 4
I/O-32
DEC-4
Dec time 4
I/O-33
ACC-5
Acc time 5
I/O-34
DEC-5
Dec time 5
I/O-35
ACC-6
Acc time 6
I/O-36
DEC-6
Dec time 6
I/O-37
ACC-7
Acc time 7
I/O-38
DEC-7
Dec time 7
FU2-71 [Accel/Decel time scale]
l Set the Accel / Decel time unit.
Setting
Unit
Minimum 0 sec settable
0
0.01 sec
Maximum 60 sec settable
Minimum 0 sec settable
1
0.1 sec
Maximum 600 sec settable
(Factory setting)
Minimum 0 sec settable
2
1 sec
Maximum 6000 sec settable*
* Up to 6000 sec setting is available via LE-200 keypad.

DRV-03: Drive Mode (Run/Stop Method)

DRV? Drive mode
03
Keypad
Factory Default:
Fx/Rx-1
Select the source of run/stop command.
Setting Range
LCD
7-Seg
0
Keypad
Run/Stop is controlled by Keypad.
Control Terminals FX, RX and 5G
Fx/Rx-1
1
control Run/Stop. (Method 1)
Control Terminals FX, RX and 5G
Fx/Rx-2
2
control Run/Stop. (Method 2)
XCEL-
XCEL-
XCEL-
Factory
H
M
L
setting
0
0
0
10 sec
0
0
0
20 sec
0
0
1
20 sec
0
0
1
20 sec
0
1
0
30 sec
0
1
0
30 sec
0
1
1
40 sec
0
1
1
40 sec
1
0
0
50 sec
1
0
0
50 sec
1
0
1
40 sec
1
0
1
40 sec
1
1
0
30 sec
1
1
0
30 sec
1
1
1
20 sec
1
1
1
20 sec
Description
03
1
1
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents