Jog Run Mode - Toshiba VF-S15 Instruction Manual

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

6.14 Jog run mode

f260 : Jog run frequency
f261 : Jog run stopping pattern
f262 : Panel jog run mode
 Function
Use the jog run parameters to operate the motor in jog mode. Input of a jog run signal immediately
generates a jog run frequency output irrespective of the designated acceleration time.
Also, you can choose the jog run start/stop mode from the panel.
Assign 18: jog run mode to an input terminal.
Ex) When assigning it to the RES terminal: f113 to 18.
The motor can be operated in jog mode while the assigned input terminals are connected (RES-CC ON).
[Parameter setting]
Title
f260
f261
f262
[Setting of jog run mode (RES-CC)]
Ex) Assign jog run mode to control terminal RES.
Title
f113
Note 1: During the jog run mode, low speed detection signal (LOW) is output but designated frequency reach
Note 2: When only the operation panel is used for operation in jog run mode, the jog run function does not need to
<Examples of jog run>
RES (JOG): ON + F:ON: Forward jog run
RES(JOG): ON + R: ON: Reverse jog run
( Frequency command + F: ON: Forward run , Frequency command + R: ON: Reverse run )
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
Jog run frequency
Jog run stopping
pattern
Panel jug run mode
Function
Input terminal selection (RES)
signal (RCH) is not output, and PID control does not work.
be assigned to any input terminal.
Adjustment range
f240-20.0 (Hz)
0: Deceleration stop
1: Coast stop
2: DC braking
0: Invalid
1: Valid
Adjustment range
0-203
F-49
E6581611
Default setting
6
5.0
0
0
Setting
18
(Jog run mode)

Hide quick links: