Adjustment Parameters - Toshiba VF-S15 Instruction Manual

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

6.33 Adjustment parameters

6.33.1 Inputting integral input power pulse
 : Integral input power pulse output unit
 : Integral input power pulse output width
 Function
[Parameter setting]
 Integral input power pulse output unit
 Integral input power pulse output width
6
Setting example) When integral input power pulse is output from output terminal
 Output terminal selection 2A
There is no reverse signal.
6.33.2 Pulse train output for meters
f669 : Logic output/pulse train output selection (OUT)
f676 : Pulse train output function selection (OUT)
f677 : Maximum numbers of pulse train output
f678 : Pulse train output filter
 Function
Ex.: When operations frequencies (0 to 60Hz) are put out by means of 0 to 600 pulses
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Pulse signal can be output each time integral input power reaches integral power unit that is set by
f667 .
Pulse output width is set by f668 .
Title
Function
Title
Function
Pulse trains can be sent out through the OUT output terminals.
Set a pulse output mode and the number of pulses.
fh =60.0, f669 =1, f676 =0, f677 =0.60
Adjustment range
0: 0.1kWh
1: 1kWh
2: 10kWh
3: 100kWh
0.1-1.0 (s)
Adjustment range
0 - 255
F-120
E6581611
Default setting
1
0.1
Setting
180: IPU (Integral input
power pulse output signal)