Toshiba VF-S15 Instruction Manual page 341

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

<Continued>
Item
Protective function
Electronic thermal
characteristic
Reset function
Alarms
Causes of failures
Monitoring function
Past trip monitoring
function
Output for frequency
meter
4-digit 7-segments LED
Indicator
Location of use
Elevation
Ambient temperature
Storage temperature
Relative humidity
Note 1. Maximum output voltage is the same as the input voltage.
Note 2. A chattering (momentary ON/OFF of contact) is generated by external factors of the vibration and the impact, etc. In
particular, please set the filter of 10ms or more, or timer for measures when connecting it directly with input unit
terminal of programmable controller. Please use the OUT terminal as much as possible when the programmable
controller is connected.
Note 3. Current must be reduced by 1% for each 100 m over 1000 m. For example, 90% at 2000m and 80% at 3000m.
Note 4. When using the inverter in locations with temperatures above 40°C, remove the protective label on the top of the
inverter and use the inverter with the output current reduced according to section 6.18.
.
To align the inverters side-by-side horizontally, remove the protective label on the top of the inverter before use. When
using the inverter in locations with temperatures above 40°C, use the inverter with the output current reduced.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Stall prevention, current limitation, over-current, output short circuit, over-voltage, over-voltage limitation,
undervoltage, ground fault detection, input phase failure, output phase failure, overload protection by electronic
thermal function, armature over-current at start-up, load side over-current at start-up, over-torque, undercurrent,
overheating, cumulative operation time, life alarm, emergency stop, braking resistor overcurrent / overload,
various pre-alarms
Switching between standard motor and constant-torque VF motor, switching between motors 1 & 2, setting of
overload trip time, adjustment of stall prevention levels 1 & 2, selection of overload stall
Panel reset / External signal reset / Power supply reset. This function is also used to save and clear trip records.
Overcurrent, overvoltage, overload, overheat, communication error, under-voltage, setting error, retry in process,
upper/lower limits
Overcurrent, overvoltage, overheat, output short-circuit, ground fault, overload on inverter, arm overcurrent at start-
up, overcurrent on the load side at start-up, CPU fault, EEPROM fault, RAM fault, ROM fault, communication error.
(Selectable: dynamic braking resistor overload, emergency stop, under-voltage, small current, over-torque, low-
torque, motor overload, input phase failure, output phase failure)
Output frequency, frequency command value, operation frequency command, forward/reverse run, output current,
input voltage (DC detection), output voltage, torque, inverter load factor, motor load factor, braking resistor load
factor, input power, output power, information on input terminals, information on output terminals, overload and
region setting, version of CPU1, version of CPU2, PID feedback value, stator frequency, causes of past trips 1to 8,
parts replacement alarm, cumulative operation time, number of starting
Stores data on the past eight trips: number of trips that occurred in succession, output frequency, frequency
command value, forward/reverse run, output current, input voltage (DC detection), output voltage, information on
input terminals, information on output terminals, and cumulative operation time when each trip occurred.
Analog output for meter:
1mA dc full-scale dc ammeter
0 - 20mA (4 to 20mA) output: DC ammeter (allowable load resistance: 600Ω or less)
0 - 10V output:
DC voltmeter (allowable load resistance: 1kΩ or more)
Maximum resolution:
1/1000
Frequency:
inverter output frequency.
Alarm:
overcurrent alarm "c", overvoltage alarm "p", overload alarm "l", overheat alarm "h",
communication alarm "t".
Status:
inverter status (frequency, cause of activation of protective function, input/output voltage, output
current, etc.) and parameter settings.
Free-unit display: arbitrary unit (e.g. rotating speed) corresponding to output frequency.
Lamps indicating the inverter status by lighting, such as RUN lamp, MON lamp, PRG lamp,  lamp, Hz lamp.
The charge lamp indicates that the main circuit capacitors are electrically charged.
Indoors; not exposed to direct sunlight, corrosive gas, explosive gas, flammable gas, oil mist, or dust; and vibration
2
of less than 5.9m/s
(10 to 55Hz).
3000 m or less (current reduction required over 1000 m) Note 3)
-10 to +60°C Note 4)
-25 to +70°C
5 to 95% (free from condensation and vapor).
Specification
L-3
E6581611
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents