11.3 Extended parameters
 Input/output parameters 1
Communication
Title
No.

0100

0101

0102

0104

0105

0107

0108

0109

0110

0111

0112

0113

0114

0115

0116

0117

0118
*6: Refer to section 11.6 for details about input terminal function.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Low-speed signal
Hz
0.1/0.01
output frequency
Speed reach
Hz
0.1/0.01
setting frequency
Speed reach
Hz
0.1/0.01
detection band
Always active
-
function selection 1
Priority selection
-
(Both F and R are
ON)
Analog input
-
terminal selection
(VIB)
Always active
-
function selection 2
Analog/logic input
-
selection
(VIA/VIB)
Always active
-
function selection 3
Input terminal
-
selection 1A (F)
Input terminal
-
selection 2A (R)
Input terminal
-
selection 3A (RES)
Input terminal
-
selection 4A (S1)
Input terminal
-
selection 5 (S2)
Input terminal
-
selection 6 (S3)
Input terminal
-
selection 7 (VIB)
Input terminal
-
selection 8 (VIA)
Adjustment range
0.0-
0.0-
0.0-
0-7, 10-153: *6
-
8,9: -
-
0: Reverse
1: Deceleration Stop
-
0: 0-+10V
1: -10-+10V
-
0-7, 10-153: *6
8,9: -
0: VIA - analog input
-
VIB - analog input
1: VIA - analog input
VIB - contact input
2: -
3: VIA - contact input (Sink)
VIB - contact input
4: VIA - contact input (Source)
VIB - contact input
-
0-7, 10-153: *6
8,9: -
-
0-203 *6
-
-
-
-
-
-
-
8-55 *6
K-5
E6581611
Default
User
Reference
setting
setting
0.0
6.5.1
0.0
6.5.3
2.5
6.5.2
6.5.3
0 (No
6.7.1
function)
1
6.6.1
0
6.6.2
6.10.2
7.3
0 (No
6.7.1
function)
0
6.6.3
6.7.2
6.10.2
7.2.1
7.3
6
6.7.1
(ST)
2
6.7.2
(F)
7.2.1
4
(R)
8
(RES)
10
(SS1)
12
(SS2)
14
(SS3)
16
(SS4)
24
(AD2)
11

Hide quick links: