Installation Diagram Metpoint ® Ocv With Activated Carbon Adsorber - Beko METPOINT OCV Installation And Operation Manual

Oil vapour measuring device with sampling probe
Table of Contents

Advertisement

Installation
10.2 Installation diagram METPOINT
1
Compressor
2
Cyclone separator with BEKOMAT
3
Compressed-air tank
4
BEKOMAT for the tank drainage
5
Fine filter (F) with BEKOMAT
6
Minimum requirement: refrigeration dryer
7
Super-fine filter (S) with BEKOMAT
8
Activated-carbon adsorber
9
Dust filter (S) with manual drain
10
Sensor unit METPOINT
11
Evaluation unit with user interface (display) METPOINT
H1/H2
Shut-off valves of the measuring section
H3
Shut-off valve of the bypass
H4
Vent valve of the measuring section
The depicted installation shows the minimum requirement of the METPOINT
carbon adsorber. Other types of installation are possible (provided that they meet the defined operating conditions).
For service measures, it is recommended to install a bypass at the METPOINT
components to be serviced in compressed-air systems.
Please observe that this bypass must also be free from oil and grease!
CAUTION!
Contaminated input air – inferior operating conditions!
When employing the METPOINT
damaged or destroyed!
22
®
OCV with activated carbon adsorber
®
OCV
®
OCV under inferior operating conditions, the device can be contaminated,
Oil-and grease-free
®
OCV
zone
®
OCV in combination with an activated-
®
OCV. This applies generally to all
METPOINT
®
OCV