6.2.14

Relay and sensor on the HiPath 1120

Programmed
Code
Functions
Sensor function
170
configuration
Sensor Activation
174
Logic
Time between
050
attempts for acti-
vating the sensor
MSN assignment
051
for the sensor
Number dialed by
052
sensor activation
Number of
053
attempts for acti-
vating the sensor
DTMF signals for
177
the sensor
*
Relay
175
Timer for deactivat-
173
ing the relay
External ring for
071
activating the relay
*
When playing music from an external music source, all regulations relating to copyrights for the country in question have
to be followed.
Table 6-23
Relay and sensor on the HiPath 1120
Service Manual
Intermediate data
extension
Configuring the system specifically for the client
Table of the System's Programming Codes
Data to be
programmed
0 = Deactivate the
sensor's function (default)
1 = Dial the number speci-
fied in "Number dialed by
sensor activation" (Code
052).
2 = Activate the relay
through the sensor
3 = Detect DTMF code.
When this setting is
selected, the number that
was called must acknowl-
edge or ignore an alarm
call by sending an
acknowledgement code
("#" DTMF signal)
0 - Contacts closed
1 - Contacts open
Time: 00 to 10 minutes
Position: 001 to 140 or
- to delete
Number (up to 20 digits)
001 to 100 (attempts)
Number (up to 20 digits)
# - To confirm
1 - Switch
2 - Monoflop
3 - Invert
4 - Music on Hold
5 - External signal
000 to 255
(intervals of 0.5 s)
Completing
Default
data entry
Automatic
0
# instead of
0 - Contacts
the sensor
closed
Automatic
03 (3
minutes)
Automatic
None
Automatic or
None
#
Automatic
001 (1
attempt)
Automatic or # None
Automatic
1 - Switch
# instead of
002 - (1
number
second)
Automatic
None