Configuring the system specifically for the client
Comments about the system's programming codes
6.3.8
Internal entrance telephone
Configuring an internal entrance telephone (115)
This function enables the system to use an entrance telephone. You can connect up to 20 entrance telephones in extension
slots. Each entrance telephone must be individually activated in the system.
1.
By default no slot is set as an entrance telephone.
2.
Only one entrance telephone may be connected to each module of the TFE
interface.
3.
Each TFE module works as an entrance telephone OR pager interface. To use
both functions, two modules are required.
Door Lock (116)
This feature detects when there is a locking device installed in a given slot in the internal entrance telephone.
DIDs for entrance telephones (159)
It specifies the extensions that will be called during day or night service when the entrance telephone is activated.
The default setting is extension 11/101.
Permissions for the door opener (125)
If there is a locking device installed in given slots in the internal entrance telephone, permission will be required for opening
the door in the required slots.
This class of service is assigned to all extensions by default.
6.3.9
Call Detail Report Manager
Information about calls received and made are stored in the system's memory. CDR records can be reviewed in the following
manner:
By using a PC or printer connected through a serial interface.
●
By using a PC connected on a local network.
●
The tickets list can be viewed on a Billing Application installed in the PC or through Windows' Hyper Terminal.
For the Windows' Hyper Terminal, HiPath 1100 makes available a local control of ticket
●
purchasing at any time through a series of commands that can be programmed into the
application interface with the central.
6-262
Service Manual