Mitsubishi Electric GOT2000 Connection Manual page 178

Graphic operation terminal
Hide thumbs Also See for GOT2000:
Table of Contents

Advertisement

(3) Setting on the CP1H, CP1L
Dip switch
Switch
SW4
SW5
(4) Setting on the CP1E
Settings by DIP switch are not required.
4 - 24
4. CONNECTION TO OMRON PLC
4.2 Serial Connection
Description
Settings
Option
Board
OFF
Slot1
According
to PLC
Setup.
Option
Board
OFF
Slot2
Setting PLC system settings
(1) CJ1, CJ2, CS1
Make the PLC system settings.
Channel
Bit
Arbitrary
15
settings ON/
OFF
Serial
8 to 11
communication
160
mode
3
Data bit
2
Stop bit
0 to 1
Parity
Port
transmission
161
0 to 7
speed
Host link station
163
0 to 7
No.
*1
Only transmission speeds available on the GOT side are
shown.
*2
Set the same port transmission speed as that of the GOT
side.
*3
Set the host link station No. according to the Host Address
on the GOT side.
HINT
HINT
HINT
Precautions for changing the PLC system settings
Before changing the PLC system settings, make sure
that the switch settings have been changed as follows:
CJ1, CJ2, CS1: Front panel DIP switch SW5 to "OFF"
Item
Set value
1
: Arbitrary settings
H
(fixed)
0
: Upper link (fixed)
H
0
: 7bits (fixed)
H
0
: 2bits (fixed)
H
0
: Even (fixed)
H
00
: 9600bps
H
05
: 4800bps
H
06
: 9600bps
H
07
: 19200bps
H
*1*2
08
: 38400bps
H
09
: 57600bps
H
0A
: 115200bps
H
0
to 1F
H
H
*3
: No.00 to 31