Mitsubishi Electric MELSEC IQ-R series Reference Manual page 277

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

■Data communication in binary code
(Request data)
Programmable controller
Cycle time unit
CPU monitoring function
Subcommand
Cycle time
30
06
00
00
01
1E
00
H
H
H
H
H
H
H
Word device registration (First point)
Number of
Monitoring start
registered points
device
00
00
00
A8
04
H
H
H
H
H
D0 to D3
Bit device registration (first point)
Number of
Monitoring start
registered points
device
00
00
00
90
02
H
H
H
H
H
M0 to M31
(Response data)
Number of registered word blocks
Programmable
Number of registered bit blocks
controller CPU
monitoring function
CPU error monitoring
02
21
01
02
01
01
H
H
H
H
H
H
Word device registration
Number of
Monitoring
registered
start device
points
00
00
00
A8
04
H
H
H
H
H
(First point)
CPU status information
00
00
00
01
01
H
H
H
H
H
In the figure (1) and (2), set the value to "Binary code" in the tables of "Device data" of each response data.
The order of device data differ depending on the setting of "Word/byte units designation" in Engineering tool.
Number of registered word blocks
Number of registered bit blocks
Transmission
method
CPU error monitoring
01
00
02
01
01
H
H
H
H
H
Word device registration (Second point)
Monitoring
Monitoring
Monitoring start
condition
condition value
device
00
00
00
00
00
00
10
00
H
H
H
H
H
H
H
W100 to W107
CPU error monitoring registration (Fixed value)
Monitoring
Monitoring
condition
condition value
00
00
00
00
00
00
00
00
H
H
H
H
H
H
H
Bit device registration
Device data
(1)
00
H
(Second point)
00
01
00
00
00
H
H
H
H
H
13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
Number of
Monitoring
Monitoring
registered points
condition
condition value
B4
08
00
00
00
00
00
H
H
H
H
H
H
H
H
01
01
00
05
00
01
00
H
H
H
H
H
H
H
H
Number of
Monitoring
registered
Device data
start device
points
00
00
00
90
02
00
H
H
H
H
H
H
(First point)
13.5 Programmable controller CPU monitoring function
(2)
13
275

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series