Copy file (command: 1206)

The following examples show the procedure to copy a file. (For QnACPU)
The maximum number of data bytes to be copies per one time is static. For the data which are already written, adjust the
offset address and number of copy bytes, and divide them and write to the new registration file for several times.
Message format
■Request data
ASCII
Subcommand
Keyword
Setting flag
Keyword
Setting flag
Setting
Keyword Drive
Subcommand
flag
Setting
Keyword
flag
■Response data
There is no response data for this command.
An error occurs If one of the following files is specified while the QnACPU is in RUN, and error end code will
be returned.
• Parameter file
• Currently executing file in the built-in RAM (drive name: 00H)
Drive name
File No.
File name
Copy source
File name
Drive name
File No.
Copy destination
File
File No.
Extension Attribute
name
name
Copy source
File
Drive
File No.
Extension Attribute
name
name
Copy destination
Extension Attribute
Offset address
Extension Attribute
Offset address
Number
Offset
Copy
of bytes
address
mode
read
Offset
address
15 QnACPU DEDICATED COMMANDS
Number
of bytes
Copy mode
read
15.3 File Control