Commands for 1E frame

: Executable, :Not executable
Function
Device memory
Batch read
Batch write
Test (random
write)
Register
monitor
*3
data
Monitor
Extended file
Batch read
register
Batch write
Test (random write)
Register monitor data
Monitor
Direct read
Direct write
Special function
Batch read
module
Batch write
*1 When accessing Universal model QCPU, use the module with a serial number whose first five digits are '10102' or later. If using a
module with a serial number whose first five digits are '10101' or earlier, access with 3E/4E frame.
In addition, when accessing a built-in Ethernet port CPU, refer to the following manual.
 QnUCPU User's Manual (Communication via Built-in Ethernet Port)
*2 Read/write the devices within the range of AnACPU. The added new devices and their ranges cannot be specified.
*3 The devices that can be registered to E71 is for 1 command out of the three types of commands (06H, 07H, 1AH).
The specified device recently used by any of the above commands is registered to E71.
APPENDICES APPENDIX
476
Appendix 6 Accessible Modules for Each Command
Command
Access target
CPU module
L
*2
Bit units
00H
*2
Word units
01H
*2
Bit units
02H
*2
Word units
03H
*2
Bit units
04H
*2
Word units
05H
*2
Bit units
06H
*2
Word units
07H
Bit units
08H
Word units
09H
17H
18H
19H
*3
1AH
1BH
3BH
3CH
0EH
0FH
Reference
*1
Q
Qn
A
QS
A
*2
*2
*2
Page 403 Batch read in bit units (command: 00)
*2
*2
*2
Page 405 Batch read in word units (command: 01)
*2
*2
Page 407 Batch write in bit units (command: 02)
*2
*2
Page 409 Batch write in word units (command: 03)
*2
*2
Page 410 Test in bit units (random write) (command:
04)
*2
*2
Page 412 Test in word units (random write) (command:
05)
*2
*2
Page 415 Register monitor data(command: 06, 07)
*2
*2
Page 416 Monitor in bit units (command: 08)
Page 417 Monitor in word units (command: 09)
Page 419 Batch read (command: 17)
Page 421 Batch write (command: 18)
Page 423 Test (random write) (command: 19)
Page 426 Register monitor data (command: 1A)
Page 427 Monitoring (command: 1B)
Page 428 Direct read (command: 3B)
Page 430 Direct write (command: 3C)
Page 434 Batch read (command: 0E)
Page 436 Batch write (command: 0F)