Label access
Function
Batch read
Batch read
and write
array type
labels
Batch write
array type
labels
Random read
Random read
and write
labels
Random write
labels
Buffer memory access
Function
Buffer
Batch read
memory
Batch write
Intelligent
Batch read
function
Batch write
module
Module control
Function
Remote
Remote RUN
control
Remote STOP
Remote
PAUSE
Remote latch
clear
Remote
RESET
Read CPU
model name
Remote
Unlock
password
Lock
Loopback test
Clear error
Turn indicator
information
LED OFF,
initialize
communication
error
information/
error code
7 COMMANDS AND FUNCTIONS
64
7.1 Command List
Command
Description
041A
Read the values from array type labels.
Read the values in batch with specifying the consecutive array elements.
Specify the array type labels or array type elements of structure type labels.
141A
Write the values to array type labels.
Write the values in batch with specifying the consecutive array elements.
Specify the array type labels or array type elements of structure type labels.
041C
Read values with specifying multiple labels.
141B
Write values with specifying multiple labels.
Command
Description
0613
Read data from the buffer memory of the host station (supported device).
1613
Write data to the buffer memory of the host station (supported device).
0601
Read intelligent function module buffer memory data.
1601
Write intelligent function module buffer memory data.
Command
Description
1001
Perform remote RUN to the access target module.
1002
Perform remote STOP to the access target module.
1003
Perform remote PAUSE to the access target module.
1005
Perform remote latch clear to the access target module.
1006
Perform remote RESET to the access target module.
0101
Read model name and model code from the access target module.
1630
Specify a remote password to enable communications with other devices.
(Change a device from the locked state to unlocked state.)
1631
Specify a remote password to disable communications with other devices.
(Change a device from the unlocked state to locked state.)
0619
Test to check whether communications between external device and connection
station operate normally.
1617
Turn OFF the error LED, and initialize communication error information and error
code.
Subcommand
0000
For MELSEC
iQ-R series
0000
For MELSEC
iQ-R series
0000
For MELSEC
iQ-R series
0000
For MELSEC
iQ-R series
Subcommand
0000
0000
0000
0000
Subcommand
0000
0000
0000
0000
0000
0000
0000
0000
0000
000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series

Table of Contents