17.3

Command and Function Lists for 1C Frame

Use the following commands for data communication using 1C frame.
Function
Device memory
Batch read
*1
Batch write
Test (random
write)
Register
*2
monitor data
Monitor
Extended file
Batch read
register
Batch write
Direct read
Direct write
Test (Random write)
Register monitor data
Monitor
Special function
Batch read
module
Batch write
Loopback test
*1 Use the dedicated commands for extended registers to read/write extended file registers from/to ACPU.
*2 The devices for the five types of commands (BM, JM, WM, QM, EM) for registering monitor data can be registered simultaneously in
C24 for each interface.
ACPU common command, AnA/AnUCPU common command
ACPU common command is a communication function issued by MC protocol. The command is accessible for ACPU.
AnA/AnUCPU common command is a command for AnACPU and AnUCPU. The command cannot be executed for other
than AnA/AnUCPU.
: Executable, : Executable (with restrictions), : Not executable
Type
ACPU common command
AnA/AnUCPU common command
When accessing modules other than ACPU, there is a restriction for the accessible device range.
Page 350 Considerations when accessing devices other than ACPU module
ACPU
AnA/
common
AnUCPU
command
common
command
Bit units
BR
JR
Word units
WR
QR
Bit units
BW
JW
Word units
WW
QW
Bit units
BT
JT
Word units
WT
QT
Bit units
BM
JM
Word units
WM
QM
Bit units
MB
MJ
Word units
MN
MQ
ER
EW
Word units
NR
Word units
NW
ET
*2
EM
Word units
ME
TR
TW
TT
ACPU other than AnA/
AnUCPU
Description
Reads bit devices (X, Y, M, etc.) in 1-point units.
Reads bit devices (X, Y, M, etc.) in 16-point units.
Reads word devices (D, T, C, etc.) in 1-point units.
Writes bit devices (X, Y, M, etc.) in 1-point units.
Writes bit devices (X, Y, M, etc.) in 16-point units.
Writes word devices (D, T, C, etc.) in 1-point units.
Set/reset devices and device numbers to bit devices (X, Y, M, etc.) by
specifying them randomly in 1 point unit.
Set/reset devices and device numbers to bit devices (X, Y, M, etc.) by
specifying them randomly in 16 point units.
Write devices and device numbers to word devices (D, T, C, etc.) by
specifying them randomly in 1 point units.
Registers bit devices (X, Y, M, etc.) to be monitored in 1-point units
Registers bit devices (X, Y, M, etc.) to be monitored in 16-point units.
Registers word devices (D, T, C, etc.) to be monitored in 1-point units.
Monitors the devices registered by monitor data registration.
Reads extended file register (R) in 1-point units.
Writes extended file register (R) in 1-point units.
Read data in 1 point units by specifying the consecutive device number
regardless of the block number of extended file register.
Write data in 1 point units by specifying the consecutive device number
regardless of the block number of extended file register.
Write block numbers and device numbers to extended file register (R) by
specifying them randomly in 1 point units.
Register extended file register (R) in 1-point units.
Monitor the extended file register (R) registered by monitor data
registration.
Reads data in the buffer memory of a special function module.
Writes data to the buffer memory of a special function module.
Send (returns) characters received from an external device back to the
external device unchanged.
AnA/AnUCPU
17 COMMUNICATING USING 1C FRAMES
17.3 Command and Function Lists for 1C Frame
Module other than ACPU
349