Mitsubishi Electric MELSEC IQ-R series Reference Manual page 280

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

■Data communication in binary code
(Request data)
Cycle time unit
Subcommand
30
06
00
00
01
H
H
H
H
H
Word device registration (first point)
Monitoring
start device
00
00
00
H
H
H
D0 to D3
Bit device registration (first point)
Monitoring
start device
00
00
00
H
H
H
M0 to M31
(Response data)
When the condition (D0 = 99) of word device registration (first point) is established
Number of registered word blocks
Programmable
Number of registered bit blocks
controller CPU
CPU error monitoring
monitoring function
02
21
02
01
00
H
H
H
H
H
When the condition (M0 ≠ OFF) of bit device registration (first point) is established
Number of registered word blocks
Programmable
Number of registered bit blocks
controller CPU
CPU error monitoring
monitoring function
02
21
02
00
01
H
H
H
H
H
When the condition of CPU error monitoring is established(Module warning being generated)
Number of registered word blocks
Programmable
Number of registered bit blocks
controller CPU
CPU error monitoring
monitoring function
02
21
02
00
00
H
H
H
H
H
In the figure (1) and (2), set the value of "Binary code" in the tables of "Device data" of each response data.
The order of device data differ depending on the setting of "Word/byte units designation" in Engineering tool.
13 SERIAL COMMUNICATION MODULE DEDICATED COMMANDS
278
13.5 Programmable controller CPU monitoring function
Programmable controller
Number of registered word blocks
CPU monitoring function
Number of registered bit blocks
Transmission
Cycle time
CPU error monitoring
method
1E
00
02
00
02
01
01
H
H
H
H
H
H
H
Number of
Monitoring
Monitoring
registered points
condition
condition value
A8
04
00
01
00
63
00
H
H
H
H
H
H
H
D0=99
Number of
Monitoring
Monitoring
registered points
condition
condition value
90
02
00
02
00
00
00
H
H
H
H
H
H
H
M0≠OFF
Number of
Monitoring start device
registered points
00
00
00
00
A8
04
00
H
H
H
H
H
H
H
Word device information
Number of
Monitoring start device
registered points
00
00
00
00
90
02
00
H
H
H
H
H
H
H
Bit device information
Fixed value
01
00
01
01
00
00
00
H
H
H
H
H
H
H
CPU status information
Word device registration (second point)
Monitoring
Monitoring
Number of
condition
registered points
start device
00
10
00
B4
08
00
02
H
H
H
H
H
H
H
W100 to D107
CPU error monitoring registration (Fixed value)
00
00
00
01
01
00
05
H
H
H
H
H
H
H
Device data
(1)
Device data
(2)
Device data
01
00
00
00
H
H
H
H
Monitoring
condition value
00
00
00
H
H
H
W100≠0
00
01
00
H
H
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series

Table of Contents