CODE
FAULT
EXT FAULT 2
F0015
(programmable
fault function 3004)
EARTH FAULT
F0016
(programmable
fault function 3017)
UNDERLOAD
F0017
(programmable
fault function
3013...3015)
THERM FAIL
F0018
CURR MEAS
F0021
INPUT PHASE
F0022
LOSS
(programmable
fault function 3016)
DRIVE ID
F0026
CONFIG FILE
F0027
MOTOR PHASE
F0034
OUTP WIRING
F0035
(programmable
fault function 3023)
INCOMPATIBLE
F0036
SW
SERF CORRUPT
F0101
SERF MACRO
F0103
DSP T1
F0201
OVERLOAD
DSP T2
F0202
OVERLOAD
DSP T3
F0203
OVERLOAD
DSP STACK
F0204
ERROR
MMIO ID ERROR
F0206
CAUSE
External fault 2
Drive has detected earth (ground)
fault in motor or motor cable.
Motor load is too low due to e.g.
release mechanism in driven
equipment.
Drive internal fault. Thermistor
used for drive internal temperature
measurement is open or
short-circuited.
Drive internal fault. Current
measurement is out of range.
Intermediate circuit DC voltage is
oscillating due to missing input
power line phase or blown fuse.
Fault trip occurs when DC voltage
ripple exceeds 14% of nominal DC
voltage.
Internal drive ID fault
Internal configuration file error
Motor circuit fault due to missing
motor phase.
Incorrect input power and motor
cable connection (i.e. input power
cable is connected to drive motor
connection).
Loaded software is not
compatible.
Corrupted Serial Flash chip file
system
Active macro file missing from
Serial Flash chip
System error
Internal I/O Control board (MMIO)
fault
WHAT TO DO
Check external devices for faults.
Check fault function parameter setting.
Check motor.
Check fault function parameter setting.
Check motor cable. Motor cable length must not
exceed maximum specifications. See section
connection
on page 114.
Check for problem in driven equipment.
Check fault function parameter settings.
Check motor power against unit power.
Contact your local ABB representative.
Contact your local ABB representative.
Check input power line fuses.
Check for input power supply imbalance.
Check fault function parameter setting.
Contact your local ABB representative.
Contact your local ABB representative.
Check motor and motor cable.
Check input power connections.
Check fault function parameter setting.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
105