Abb Standard Macro - ABB ACS150 User Manual

Table of Contents

Advertisement

ABB Standard macro

This is the default macro. It provides a general purpose I/O configuration with three
constant speeds. Parameter values are the default values given in chapter
signals and
If you use other than the default connections presented below, see section
terminals
Default I/O connections
1)
See parameter group
DI3 DI4 Operation (parameter)
0
1
0
1
parameters, starting from page 63.
on page 32.
X1A
1
SCR
2
AI
3
GND
3)
4
+24V
5
GND
6
DCOM
7
DI1
8
DI2
9
DI3
10
DI4
11
DI5
X1B
12
COM
13
NC
14
NO
12 CONSTANT
0 Set speed through
integrated potentiometer
0 Speed 1 (1202)
1 Speed 2 (1203)
1 Speed 3 (1204)
Signal cable shield (screen)
Frequency reference: 0...20 mA
Analog input circuit common
Auxiliary voltage output: +24 VDC, max. 200 mA
Auxiliary voltage output common
Digital input common
Stop (0) / Start (1)
Forward (0) / Reverse (1)
Constant speed selection
Constant speed selection
Acceleration and deceleration selection
Relay output
No fault [Fault (-1)]
2)
SPEEDS:
0 = ramp times according to parameters
and 2203.
1 = ramp times according to parameters
and 2206.
3)
360 degree grounding under a clamp.
Actual
I/O
1)
1)
2)
2202
2205
Application macros
57