5.8 Head base Replacement Procedure

When damaging the head base, the head base must be replaced.
following procedure.
(1) Remove all of the covers described in the item 5.1.
(2) Remove the nozzle described in the item 5.2.
(3) Remove the deflecting base described in the item 5.3.
(4) Remove the sealing valve described in the item 5.5.
(5) Remove the heating unit described in the item 5.6.
(6) Remove the gutter base described in the item 5.7.
(7) Remove the FG and NH sponges.
(8) Remove the soldering of the APH sensor board and the signal wire.
(9) Unscrew the APH sensor board setscrew.
(10) Unscrew the fastening screw between the head base and the head cable, and
remove the head base.
(11) Attach a new head base.
"Caution"
(A) Do not mix up lead wires and tubes which each is disposed on the
front face (nozzle side) and the back face (high voltage cable side).
Front face: ink-furnishing tube (E), makeup ink tube (R), circulation tube (J), air
purge.
Ink-furnishing tube (E)
Back face: excitation signal wire (pull it out from the head base opening to the
front face), G, sealing valve feeder wire, recovery tube, APH signal
wire, video signal wire, heater feeder wire, cover SW signal wire,
EZJ98 board signal wire, high voltage feeder wire
Sponge
Sealing
valve
Makeup ink tube (R)
Recovery
Excitation
Heater
Cover SW
Video
5-14
Perform it by the
Air purge
E
Circulation tube (J)
Signal side
APH
soldering
GND side
soldering
EZJ98 CN1
signal wire
High
voltage