Archiving - ABB SM500F User Manual

Field mountable paperless recorder
Hide thumbs Also See for SM500F:
Table of Contents

Advertisement

SM500F
Field mountable paperless recorder

7.7.4 Archiving

90
Select the archive file format required – Text format or Binary format.
Note.
The selected archive file format is applied automatically to
process groups. It is not possible to set each group to different
formats.
If 'Enable Batch Recording' on the 'Batch' tab is set to 'On', the
archive file format is set automatically to 'Binary format' and cannot
be changed.
Select the data types that are to be archived to the storage media:
Channel Data; Alarm Event log; Totalizer log; Audit log.
Note.
The totalizer log file can be enabled only if the totalizer option is
enabled.
Batch log files are generated automatically if batch recording is
enabled and cannot be de-selected.
File Type
Channel
Analog or digital recording channel signals in
data files
the current process group
The historical record of the alarm events
Alarm
related to the group's channels plus the
event log
history of any operator messages, electronic
files
signatures or real time alarms.
The historical record of all totalizer and
Totalizer
associated statistical values relating to the
log files
group's recording channels.
Audit log
The historical entries in the audit log.
files
Note. Displayed only if 'Archive file format' is set to 'Text format'.
Enter the filename (max. 20 characters) to be used to identify the channel
data archive files.
Note. The following characters cannot be used in the filename tag: \, /, :,
*, ?, ", <, >, |, superscript characters, ~,  and º. These are greyed-out
(color recorders) or blanked out when selected (monochrome recorders)
on the keyboard.
Contents
7 Configuration
both
Extension
*.D00 (Text)
or
*.B00 (Binary)
*.E00 (Text)
or
*.EE0 (Binary)
*.T00 (Text)
or
*.TE0 (Binary)
*.A00 (Text)
or
*.AE0 (Binary)