● Triggering
● STARTER parameterization and commissioning tool
● Settable trace cycle: integers of the base sample time
Parameterization
The "trace function" parameter screen is selected via the following icon in the toolbar of the
STARTER commissioning tool.
Figure 3-6
3.2.3

Measuring function

Description
The measuring function is used for optimizing the drive controller. By parameterizing the
measuring function, the impact of superimposed control loops can be suppressed selectively
and the dynamic response of the individual drives analyzed. The ramp-function generator
and trace function are linked for this purpose. The control loop is supplied with the ramp-
function generator signal at a given point (e.g. speed setpoint) and recorded by the trace
function at another (e.g. speed actual value). The trace function is parameterized
automatically when the measuring function is parameterized. Specific predefined operating
modes for the trace function are used for this purpose.
Parameterizing and using the measuring function
The measuring function is parameterized and operated via the parameterization and
commissioning tool STARTER.
Commissioning
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
– Without triggering (recording immediately after start)
– Triggering on signal with edge or on level
– Trigger delay and pretrigger possible
– Automatic or adjustable scaling of display axes
– Signal measurement via cursor
STARTER icon for "trace function/ramp-function generator"
Diagnosis
3.2 Diagnostics via STARTER