Heavy Load Protection Mode - Epson 0C88832 Technical Manual

Cmos 8-bit single chip microcomputer
Table of Contents

Advertisement

2 POWER SUPPLY

2.3 Heavy Load Protection Mode

The E0C88832/88862 has a heavy load protection
function for stable operation even when the supply
voltage fluctuates by driving a heavy load. The
heavy load protection mode becomes valid when
the peripheral circuits are in the following status:
(1) The OSC3 oscillation circuit is switched ON
(OSCC = "1" and not in SLEEP)
(2) The buzzer output is switched ON
(BZON = "1" or BZSHT = "1")
SLEEP status
OSCC
BZON
BZSHT
Fig. 2.3.1 Configuration of heavy load protection mode
control circuit
For details of the OSC3 oscillation circuit and
buzzer output, see "5.3 Oscillation Circuits and
Operating Mode" and "5.12 Sound Generator",
respectively.
12
Heavy load
protection mode
EPSON