GT16H-CNB-42S
Terminal block 2
Terminal No.
11
12
13
14
(2) Wiring to the terminal block
Terminal screws are M3.
Wire as described below.
Do not tighten the terminal screws with the torque outside the specified range.
Doing so can cause a failure or malfunction.
6.2(0.24)
or less
6.2(0.24)
or less
Wire size
Solderless terminal
Tightening torque
(3) Installing and removing of external cable
When installing or removing the external cable from the Connector Conversion Box, make sure that the power switch
is turned OFF.
Connect the external cable with the Connector Conversion Box in the same procedure as connecting the external
cable with Handy GOT.
Refer to the following.
7.3.1 Installing and removing of external cable
Signal name
DSW1
DSW1
For Grip switch
DSW2
DSW2
Terminal
3.2(0.13)
screw
3.2(0.13)
When wiring one cable to
one terminal
2
For power supply: 0.75mm
or more, For grounding: 2mm
Solderless terminal for M3 (Applicable solderless terminal: RAV1.25-3, V2-N3A, FV2-N3A)
0.5N•m to 0.8N•m
Application
Terminal
Solderless
screw
terminal
When wiring two cables to
one terminal
Unit: mm (inch)
2
or more
7.1 Connector Conversion Box
Solderless
terminal
7 - 11
7