7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
19
Default value
0
Input of parameter setting for a PT2 filter (low-pass) in the speed setpoint channel. The low-
pass filter is inserted on the output side of the ramp-function generator and is effective only if
the speed setpoint smoothing function (MD 53, bit 4) is activated at the same time.
20
Default value
0000
Display of the monitoring machine data "Diagnosis speed actual value". If an impermissibly
large speed deviation occurs within the sampling period, then the value of the machine data is
incremented. Sporadic responses by a few increments can be ignored since these do not
influence the speed controller. A high disturbance level will cause the contents of MD 20 to be
increased repeatedly by several increments.
Possible causes of disturbances
Encoder shield not earthed
Encoder defective
Earth connection of electronics ground in MSD module faulty
Motor earth not connected in MSD module
Value entered for motor moment of inertia too high
Evaluation electronics
21
Default value
12
Input of response value for monitoring of the PLC status message n
MD 241).
22
Default value
Rated speed
––––––––––––––
256
Input of response value for the internal n
rotation. When the speed n
stop with any remaining kinetic energy.
Note:
This n
threshold is not the same as the response value of the n
min
set to the same value.
7–4
More user manuals on
Rounding degree speed setpoint
Lower input limit
0
Diagnosis speed actual value
Lower output limit
0000
n
for n
min
act
Lower input limit
0
Creep speed pulse suppression motor 1
Lower input limit
0
min
is reached, the drive torque is cut off and the drive coasts to a
min
ManualsBase.com
Upper input limit
30
Upper output limit
< n
message motor 1
min
Upper input limit
Rated speed
act
Upper input limit
Rated speed
sensor for stopping the drive with no reverse
min
©
Siemens AG 1992 All Rights Reserved
10.94
Active
at once
Units
Active
at once
Units
Hex
Active
at once
Units
rev/min
< n
(see also
min
Active
at once
Units
rev/min
monitor, but it may be