7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Specified: Blocking frequency 1 kHz, 500 Hz bandwidth and 250 Hz bandwidth numerator
(damping)
20.0
dB
0.0
-5.0
-60.0
1
Log
180
Deg
-180
1
Log
1201
Default value
Low-pass
Input of configuration of 4 current setpoint filters. Band-stop and low-pass filters are available.
The adjustable filter parameters are entered in the appropriate machine data.
Value table:
1st filter
2nd filter
7–102
More user manuals on
10
100
10
100
Type current setpoint filter
Lower input limit
Low-pass
Bit 0
Bit 1
ManualsBase.com
1k
10 kHz
Blocking frequency
1k
10 kHz
Upper input limit
Band-stop
0
Low-pass (see MD 1202/1203)
1
Band-stop (see MD 1210/1211/1212)
0
Low-pass (see MD 1204/1205)
1
Band-stop (see MD 1213/1214/1215)
©
Siemens AG 1992 All Rights Reserved