Spindle-Specific Md (Spindle Data) - Siemens SINUMERIK 840C Installation Instructions Manual

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
6.5
400*
Default value
The spindles available on the machine can be allocated to the measuring circuit modules in a
flexible way. They are allocated separately according to actual value inputs (MD 400*) and
setpoint outputs (MD 460*).
Simulation axes/spindles are defined if no measuring system is parameterized (measuring loop
and encoder not entered in MD 200*, MD 400*).
The simulation axis/spindle generates partial actual values from the partial setpoints and
therefore travels without following error. (For more detailed description see MD 200*).
Note:
See Section 5, Machine Data Dialog, for the servo loop assignment.
401*
The input value must be modified in the appropriate direction until the spindle exhibits identical
actual speeds in both directions of rotation. The value must be adjusted at low speeds, and
can be checked by viewing the appropriate information in the Basic display in the service
display for spindles (spindles with encoder), using a rev counter, or screening the Service
data. In M 19 (spindle positioning), the spindle drift goes directly into the positioning error.
403*-410*
NC MD
Default
NC MD 403* - 410* specify the maximum spindle speed reached in the individual gears at a
setpoint of 10 V. When no gear is available, the maximum permissible spindle speed is entered
_______
1)
The input resolution is 0.1 rev/min, if MD 520* bit 3=1.
2)
Up to SW 2
3)
As from SW 3
4)
As from SW 4
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on

Spindle-specific MD (spindle data)

Measuring system connection
Lower input limit
0
0
Spindle drift compensation
Default value
Lower input limit
2)
0
0
3)
Maximum speed gear stages 1-8
Default value
Lower input limit
see table
Gear
1
2
403*
404*
500
1000
ManualsBase.com
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
Upper input limit
05031000
15021015 (up to SW 4)
30021015 (as from SW 5)
Upper input limit
–500
500
–500
500
Upper input limit
+0
99 999
3
4
405*
406*
407*
2000
4000
4000
4000
4)
6FC5197- AA50
6.5 Spindle-specific MD (spindle data)
Active on
Power On
Units
Active
at once
Units
2)
VELO
0.01% of max.
motor speed
Active on
NC Stop
Units
1)
rev/min
5
6
7
408*
409*
4000
4000
3)
8
410*
4000
6–65