SmartLogger2000
User Manual
(2016-06-20)
within 10 seconds. If STP is used, fiber ring protection can be completed within 60
seconds.
PLC
−
Has a built-in PLC CCO module through which southbound devices connect to the
SmartLogger over AC power cables.
Ethernet electrical port
−
Provides two 10/100M Ethernet electrical ports that can be used as southbound
ports to connect to southbound devices or used as northbound ports to connect to an
NMS.
A southbound port connects to a downstream device for collecting data and setting parameters.
Southbound devices include the inverter, environmental monitoring instrument (EMI), power meter,
box-type transformer, and PID module.
A northbound port connects to an upstream NMS for uploading data.
RS485
−
Supports six RS485 routes and access of devices that use Modbus-RTU, IEC103,
and DL/T645.
Graphical data
In addition to displaying the electricity yield and real-time monitoring information
−
in graphic and text format, the embedded WebUI can also display performance data
of power stations and devices in tables or curves.
The APP displays the electricity yield and real-time monitoring information in
−
graphic and text format.
Centralized monitoring
Manages a maximum of 200 devices in centralized mode and supports the access of
−
up to 80 inverters.
Allows you to monitor and manage the PV power system on the embedded WebUI,
−
for example, viewing real-time information about power stations, devices, and
faults, setting device parameters, and maintaining devices in remote mode.
Allows you to monitor the devices in the PV power system on the APP in real time,
−
such as viewing information about power stations, devices, products, and faults,
setting device parameters, and maintaining devices.
Easy maintenance
Allows users to upgrade the firmware of the SmartLogger and export data by using
−
a USB flash drive.
Allows you to upgrade the firmware of the SmartLogger, inverter, AC combiner box,
−
PLC module, and PID module, and export logs and data over the embedded WebUI.
Allows you to manage the devices connecting to the SmartLogger and classify
−
alarms over the APP.
Intelligent management
Automatically searches for and accesses Huawei inverters, AC combiner boxes,
−
PLC modules, and PID modules. If you import a parameter configuration table, the
SmartLogger can access third-party devices that support Modbus-RTU and IEC103.
Automatically assigns RS485 addresses to the connected Huawei inverters, AC
−
combiner boxes, and PID modules, and allows for RS485 address adjustment based
on ESNs to facilitate remote configuration and maintenance.
Supports remote configuration of inverter parameters over the embedded WebUI
−
and synchronizes the parameters from one inverter to other inverters in batches.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Overview
4