About This Chapter

6.1 USB Flash Drive Operations

6.2 NMS Operations
6.3 APP Operations
6.1 USB Flash Drive Operations

6.1.1 Exporting Data

Context
USB flash drives of SanDisk, Netac, and Kingston are recommended. Other brands may be
incompatible.
By exporting data, you can obtain data of active alarms, historical alarms, performance,
exception takeover logs, commissioning logs, operation logs, fault information file, and
electronic labels.
Procedure
Step 1 Insert the USB flash drive into the USB port at the bottom of the SmartLogger.
Step 2 Log in to the APP, and choose More > System Maintenance > Generate Local Maint.
Script on the main menu page. For details, see SUN2000 APP User Manual.
Step 3 Remove the USB flash drive from the USB port at the bottom of the SmartLogger, and insert
the USB flash drive into the port again.
(2016-06-20)
The generated boot script file is automatically saved in the root directory of the USB flash drive.
After the USB flash drive is connected again, the SmartLogger can automatically detect the boot script
file.