SmartLogger2000
User Manual
Table 2-5 Components required
Component
PID module (optional)
PID inductor (working
with the PID module)
SmartLogger
RS485 signal SPD
PoE module
POE SPD
CPE
Knife
switch
Scenario Without a Smart Array Controller
If the SmartLogger uses an AC power cable for communication, an MCB or a knife switch
needs to be installed to prevent device damage in the case of short circuits
(2016-06-20)
Recommended Model or
Specifications
PID01
EIFI50ohm
SmartLogger2000
SPM01A
POE35-54A or POE85-56A
POE-2A
EG860V2-C71
Fuse
Rated voltage: ≥ 500 V; rated
current: 6 A
Knife
Rated voltage: ≥ 500 V; rated
switch box
current: ≥ 6 A; number of
phases: three
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Overview
Type
Quantity
Installed before
1 PCS
delivery
Installed before
1 PCS
delivery
Installed before
1 PCS
delivery
Installed before
3 PCS
delivery
Optional; can be
1 PCS
purchased from
Huawei
Optional; can be
1 PCS
purchased from
Huawei
Optional; can be
1 PCS
purchased from
Huawei
Prepared by the
3 PCS
customer
Prepared by the
1 PCS
customer
18