NEC UNIVERGE SV8300 System Maintenance Manual page 103

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

BLADE
LED STATUS
NAME
CD-4COTA/
LIVE LED is not
4COTB
flashing at 120
(COT)
IPM
CD-4ODTA
LIVE LED is not
(ODT)
flashing at 120
IPM
CD-4DIOPA
LIVE LED is not
(DIOP)
flashing at 120
IPM
CD-2BRIA
LIVE LED is not
(BRT)
flashing at 120
IPM
CD-PRTA
LIVE LED is not
(PRT/DTI)
flashing at 120
IPM
Remedial Action on Each LED Status
FAULT
CONTENT
Abnormal operation of
COT blade
Abnormal operation of
ODT blade
Abnormal operation of
DIOP blade
Abnormal operation of
BRT blade
Abnormal operation of
PRT/DTI blade
2-35
Chapter 2 TROUBLESHOOTING
FAULT INFORMATION DISPLAY
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Continued on next page
NWA-033627-001 Rev.4.0
95ch2001.fm
APRIL/16/2010