FAULT
FAULT
KIND
CONTENT
NUMBER
025
Number of
lockout sta-
tions was more
than predeter-
mined number
026
DLC blade
down
Remedial Action on Each Fault Kind
FAULT INFORMATION
Alarm kind: Terminal was cut off
Alarm kind: Short circuit was made on
the line
Alarm kind: Ring wire was grounded
2-21
Chapter 2 TROUBLESHOOTING
FAULT INFORMATION DISPLAY
REMEDIAL ACTION
Search for stations in line
1
lockout by the configura-
tion report on the PCPro.
Place the handset of any
2
station in line lockout
back onto the hook-
switch.
If the station remains in
3
the line lockout state,
check the line state (the
line between the station
and the PBX may be
shorted).
Check the cable
1
connection between the
terminal and the PBX.
Check to see if the cable
2
is cut off.
Check to see if the Tip
3
wire of the cable is
grounded.
Check to see if a short circuit
exists on the line.
Check to see if the Ring wire
of the cable is grounded.
Continued on next page
NWA-033627-001 Rev.4.0