C
CMEA
DATA
115
Automatic module reset due to Expansion
Chassis (2U) lockup
[8300R3 software required]
116
All blades lockup in Expansion Chassis
(2U)
[8300R3 software required]
Fault Kind: Restoration
031
ISDN D-channel link connection returned
to normal condition
032
CCIS link connection returned to normal
condition
035
Number of lockout stations restored to less
than predetermined number
036
DLC blade returned to normal condition
038
SMDR output buffer (SRAM) return to
normal condition from 80 % condition
[8300R3 software required]
039
SMDR output buffer (SRAM) return to
normal condition from overflow
[8300R3 software required]
03B
CS/ZT returned to normal condition
03C
LAN application returned to normal condi-
tion
050
Traffic of IP network returned to normal
condition from limit bandwidth excess
051
Traffic of IP network returned to normal
condition from warning bandwidth excess
D
DESCRIPTION
1ST DATA
MEANING
Chapter 1 MAINTENANCE SERVICES
DATA
0
External Alarm Kind
0: Fault Memory store/No output of
3
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: Fault Memory store/No External
Alarm output
External Alarm Kind
0: Fault Memory store/No output of
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: No Fault Memory store/No External
NOTE 8
Alarm output
NOTE 3
1-9
FAULT MESSAGE
DATA
2ND DATA
MEANING
Continued on next page
NWA-033627-001 Rev.4.0
95ch1001.fm
APRIL/16/2010