Item
When "Remote Net(Additional Mode)" is set to "Mode", set the start
device where RX, RY, RWr, and RWw (Ver.2-compatible area) of a
Ver.2 Remote Input(RX)
master/local module are transferred.
(1)
Number of refresh points
All points for the start station number to last station number of a
Ver.2 Remote
Ver.2-compatible slave station are automatically assigned.
Output(RY)
(
To use a different refresh device for each station, transfer the
Ver.2 Remote
device individually using a program (Un\G or FROM/TO
Register(RWr)
instructions).
The points for each station can be checked using Slave station
offset, size information (Un\G992 to Un\G1503). (
Ver.2 Remote
335, Appendix 2 (4))
Register(RWw)
The other contents are same as those for "Remote Input(RX)"
described the above.
Special Relay(SB)
Set the start device where SB and SW are transferred. By setting
these items, SB and SW can be automatically transferred to a device
in a CPU module without using a program.
Special Register(SW)
Retry Count
Automatic
Reconnection Station
Count
Standby Master Station
No.
The settings are not required when a master/local module is used as a
PLC Down Select
local station or standby master station. (Except when "Master
Station(Duplex Function)" is selected for "Type")
Scan Mode Setting
Delay Time Setting
Station Information
Setting
Remote Device Station
Initial Setting
Set the conditions used to issue a request for the interrupt to a CPU
Interrupt Settings
module. (
*1
The operations when the switch on a CPU module is set to STOP vary depending on whether Y or the devices other
than Y is set to "Remote Output(RY)". (
Description
Page 51, Section 3.6.5)
Page 119, Section 7.4.2 (2))
Page 133, Section 8.2.4)
CHAPTER 7 PARAMETER SETTINGS
Setting range
Same as "Remote Input(RX)"
Same as "Remote Output(RY)"
Same as "Remote Register(RWr)"
Page
Same as "Remote Register(RWw)"
Blank or the following range
• Device
M, L, B, D, W, R, SB, or ZR
(M, B, D, W, and SB for a
MELSECNET/H remote I/O station)
• Device No.
Within the device range of the CPU
module or MELSECNET/H remote
I/O station
(Default: Blank)
Blank or the following range
• Device
M, L, B, D, W, R, SW, or ZR
(M, B, D, W, and SW for a
MELSECNET/H remote I/O station)
• Device No.
Within the device range of the CPU
module or MELSECNET/H remote
I/O station
(Default: Blank)