Mitsubishi Electric MELSEC-Q Series User Manual page 331

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Address
Hexadecimal
18
to 1F
H
H
20
(First station)
H
to
5F
(64th station)
H
60
to 7F
H
H
80
(Send buffer)
H
81
(Receive buffer)
H
82
(Automatic update
H
buffer)
to
CB
(Send buffer)
203 (Send buffer)
H
204 (Receive buffer)
CC
(Receive buffer)
H
CD
(Automatic update
205 (Automatic update
H
buffer)
CE
, CF
H
H
D0
to D3
H
H
Decimal
24 to 31
prohibited)
32 (First station)
Station
to
information
95 (64th station)
96 to 127
prohibited)
128 (Send buffer)
129 (Receive buffer)
130 (Automatic update
buffer)
Assignment
of
to
communica
tion buffer
and
automatic
buffer)
update
buffer
206, 207
prohibited)
8-point
remote I/O
208 to 211
station
setting
Item
(Use
The setting status of the station type, the number of occupied
stations, and expanded cyclic setting of the connected slave
stations is stored.
Default:
0101
(Ver.1-compatible remote I/O station, one station
H
occupied, and station number 1) to 0140
remote I/O station, one station occupied, and station number
64)
Range: Refer to the following.
b15
to
b12b11
to
Number of
Station type
occupied stations
0
: Ver.1-compatible remote I/O station
H
1
: Ver.1-compatible remote device station
H
2
: Ver.1-compatible intelligent device station
H
5
: Ver.2-compatible remote device station (single)
H
6
: Ver.2-compatible intelligent device station (single)
H
8
: Ver.2-compatible remote device station (double)
H
9
: Ver.2-compatible intelligent device station (double)
H
B
: Ver.2-compatible remote device station (quadruple)
H
C
: Ver.2-compatible intelligent device station (quadruple)
H
E
: Ver.2-compatible remote device station (octuple)
H
F
: Ver.2-compatible intelligent device station (octuple)
H
(Use
The buffer memory sizes assigned for a local station,
intelligent device station, and standby master station during
transient transmission are stored.
Default
Send buffer size: 40
H
Receive buffer size: 40
Automatic update buffer size: 80
Range
• Communication buffer:
0
(0) (word) (not set) or 40
H
Note that the total size of the communication buffer must be within
1000
(4096) (word).
H
• Automatic update buffer:
0
(0) (word) (not set) or 80
H
Note that the total size of the automatic update buffer must be within
1000
(4096) (word).
H
(Use
The station number of the remote I/O station where eight
points have been set in the remote I/O station points setting is
*1 *2
stored.
Default: 0 (Not set)
Range: The bit corresponding to the station number turns on.
APPENDICES
Description
(Ver.1-compatible
H
b8b7
to
Station No.
1 to 64
(01
H
1
: Number of occupied stations: 1
H
2
: Number of occupied stations: 2
H
3
: Number of occupied stations: 3
H
4
: Number of occupied stations: 4
H
(64) (word)
(64) (word)
H
(128) (word)
H
(64) (word) to 1000
(4096) (word)
H
H
(128) (word) to 1000
(4096) (word)
H
H
A
b0
to 40
)
H
329

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents