Mitsubishi Electric MELSEC-Q Series User Manual page 235

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

(2) Assignment of the remote I/O (RX, RY) and remote register (RWr, RWw)
In the program example, the following assignment is used to perform data link.
The status of a device assignment can be checked on GX Works2 by setting information of a slave station on the CC-Link
configuration window on GX Works2. (
[View]
[Docking Window]
Remark
● When a master station is in the remote net Ver.2 mode or remote net additional mode
In the system configuration of the program example, the assignment is the same as that in the remote net Ver.1 mode,
except for buffer memory addresses of data storage locations. (
● The remote I/O (RX/RY) and remote register (RWr/RWw) of the AJ65VBTCU-68ADVN and AJ65VBTCU-68DAVN
For details on the signals, refer to the following.
Manual for the remote station used
(a) Remote input (RX)
Plan the assignment using the assignment sheet on Page 407, Appendix 8.1 (1).
CPU module
Master station
Buffer memory address
Device
Hexadecimal
E0
X1000 to X100F
H
E1
X1010 to X101F
H
E2
X1020 to X102F
H
E3
X1030 to X103F
H
E4
X1040 to X104F
H
E5
X1050 to X105F
H
E6
X1060 to X106F
H
E7
X1070 to X107F
H
E8
X1080 to X108F
H
E9
X1090 to X109F
H
EA
X10A0 to X10AF
H
EB
X10B0 to X10BF
H
Page 102, Section 7.3.2 (2) (a))
[Device Reference]
Station number
Decimal
224
1
225
226
2
227
228
3
229
230
4
231
232
5
233
234
6
235
CHAPTER 10 PROGRAMMING
Page 48, Section 3.6.4, Page 51, Section 3.6.5)
Slave station
Module name
Remote I/O (RX/RY)
AJ65VBTCU-68ADVN
RX10 to RX1F
RX20 to RX2F
AJ65VBTCU-68ADVN
RX30 to RX3F
RX40 to RX4F
AJ65VBTCU-68ADVN
RX50 to RX5F
AJ65VBTCU-68DAVN
RX10 to RX1F
RX20 to RX2F
AJ65VBTCU-68DAVN
RX30 to RX3F
RX40 to RX4F
AJ65VBTCU-68DAVN
RX50 to RX5F
10
RX0 to RXF
RX0 to RXF
233