Mitsubishi Electric MELSEC-Q Series User Manual page 356

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Number
Name
SW0060
Mode setting
(660
)
status
H
SW0061
Host station
(661
)
number
H
SW0062
Module
(662
)
operating status
H
SW0064
No. of retries
(664
)
information
H
No. of
SW0065
automatic return
(665
)
H
stations
SW0066
Delay timer
(666
)
information
H
SW0067
Parameter
(667
)
information
H
SW0068
Host parameter
(668
)
status
H
354
Mode setting status is stored.
0: Online (remote net mode)
1: Online (remote I/O net mode)
2: Offline
3: Line test 1
4: Line test 2
6: Hardware test
The current host station number is stored.
0: Master station
1 to 64: Local station
The operation setting configured using the parameter is stored.
b15
b14 b13
b12 b11b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0 0
0 0
0
The set number of retries upon an error response is stored.
1 to 7 (time)
The set number of automatic return stations in one link scan is stored.
1 to 10 (station)
The set delay time is stored.
The parameter setting used is stored.
0
: Parameter written to the CPU module
H
3
: Parameter setting and data link start using the dedicated instruction
H
(G(P).RLPASET)
D
: Default parameter (automatic CC-Link startup)
H
Whether the parameters have been correctly set is stored.
0: Correct
Values other than 0: Error code (
Description
Station type
0: Master station/local station
1: Standby master station (Valid only when b1 is 0)
Master station duplex function
0: Master station duplex function disabled
1: Master station duplex function enabled
Status of input data from a data link faulty station
0: Clear
1: Hold
Number of occupied stations
00: Number of occupied stations: 1
10: Number of occupied stations: 2
11: Number of occupied stations: 3
01: Number of occupied stations: 4
Master station/local station start by dedicated instruction
0: Start by CPU parameter
1: Start by dedicated instruction
Slave station refresh/compulsory clear setting in
case of programmable controller CPU STOP
0: Refresh
1: Clears compulsorily
Expanded cyclic setting
00: Single
01: Double
10: Quadruple
11: Octuple
Block guarantee of cyclic data per station
0: Not set
1: Set
Automatic detection of connected devices
0: Not read the model name of the slave stations
1: Read the model name of the slave stations
Page 293, Section 11.3.2)
Availability
( : Yes, ×: No)
Online
Offline
Master
Local
station
station
×
×
×
×
×
×
×
×
×