Operation_Australia Machine - Electrolux IC4 4819 FFS Service Manual

Feeder ironer folder & stacker
Table of Contents

Advertisement

Service
Manual

Operation_Australia machine

Controlled by the ELECTROLUX ITS, the A13 igniter controls the ignition of the gas pipe burner
when the machine is switched on using the A12 fl ame control box.
The ELECTROLUX ITS checks the operation of the A13 igniter using the KA10 relay.
The ignition of the gas pipe burner is carry out by the Y3/Y4 electrovalves and the E1, E2 and
E3 electrodes, once the fault gas (KA10) is validated by the ELECTROLUX ITS.
In order to protect the heating system, the B5 pressostat check the gas pressure and the B4
pressostat check the product of combustion.
The B126, B127 and B128 temperature sensor (PT100) contribute to the regulation of the
temperature and the overheating detection of ironing cylinder according to the following
condition:
Overheating condition:
Overheating on side
Overheating on center
The F2 thermal fuse (> 240°C) and the B3 safety thermostat (> 210°C) are used like thermal
breaker to protect the machine against overheating > 210°C.
Power supply
3 phases
Q0
24
ARU
KA12
E1 - E2
B4
04102011/GB
50.2011
400
Q1
T1
T2
X118
X129
A1_BASE
KA14
KA15
230
230
KA10
KA11
Gas heating
= 1
when B126 >230°C or B128 > 230°C
= 0
when B126 & B128 < 200°C
= 1
when B127 > 240°C
= 0
when B127 < 240°C
* ARU = Security chain, emergency push button
230
Q3
F2
B3
B5
X108
X109
X110
X116
KA13
A13
A12
Y3 - Y4
E3
B2
X111
X126
X127
X128
B126
B127
B128
25
X117
5