Before any intervention it is essential to cut off all supply of the machine

Repair

Replacement of the DP41 and DP42 photocell:

Under voltage, the photocell must operated according to the following conditions:
- presence of linen = the indicator is orange.
- no presence of linen = the indicator is green.
If the above conditions are not validate, the photocell is faulty.
Remove / Assembly:
1. Remove the right side frame of the stacker.
2. Disconnect the wire of the faulty photocell.
3. Remove the photocell and replace it by a new one.
4. Connect the wire on the new photocell.
5. Adjust the new photocell according to the refl ector (green indicator switches on).
6. Put back the frame.

Replacement of the KM13, KM14 and KM15 contactors:

If the contact of the contactor do not stick when the contact coil is supplied manually, this means
that the contactor is faulty.
Remove / Assembly:
1. Remove the right side frame of the stacker.
2. Remove the wire of the faulty contactor.
3. Remove the contactor and replace it by a new one.
4. Connect the wire on the new contactor.
5. Put back the frame.

Replacement of the DP43 inductive detector:

The indicator of the detector must lit when we put a metal part on the detector. If it is not the
case, the detector is faulty.
Remove / Assembly:
1. Remove rear housing of the stacker.
2. Disconnect the wire of the faulty detector.
3. Remove the detector and replace it by a new one.
4. Connect the wire on the new detector.
5. Adjust the new detector at a distance from 2 or 3 mm compared to the part to be detected
(the indicator of the detector lights).
6. Put back the frame.
04102011/GB