Repair
Replacement of the V4 jack:
Remove / Assembly:
1. Remove the left side frame of the machine.
2. Disconnect the air supply of the faulty jack.
3. Disconnect the jack from the rod linkage.
4. Remove the jack and replace it by a new one.
5. Put the new jack on the rod linkage.
6. Connect the air supply on the new jack.
7. Put back the frame.
Replacement of the DP5 inductive detector:
The indicator of the detector must lit when we put a metallic object on the detector. If it is not the
case, the detector is faulty.
Remove / Assembly:
1. Remove the left frame of the machine.
2. Remove the wire of the faulty detector.
3. Remove the detector and replace it by a new one.
4. Connect the wire on the new detector.
5. Adjust the new detector at a distance from 2 or 3 mm compared to the part to be detect
(the indicator of the detector lights).
6. Put back the frame.
Replacement of the pressostat, the air pilot valve and the pneumatic block:
see chapter «Compressed air system»