Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair
Replacement of the DP3, DP4, DP5 and DP22 inductive detectors:
The indicator of the detector must lit when we put a metal part on the detector. If it is not the
case, the detector is faulty.
Remove / Assembly:
1. Remove the left side frame of the machine.
2. Disconnect the wire of the faulty detector.
3. Remove the detector and replace it by a new one.
4. Connect the wire on the new detector.
5. Adjust the detector at a distance from 2 or 3 mm compared to the part
to detect (the indicator of the detector lights).
6. Put back the frame.
Replacement of the DP1 inductive detector:
The indicator of the detector must fl ashed when the ironing cylinder is in motion. If it is not the
case, the detector is faulty.
Remove / Assembly:
1. Remove the left side frame of the machine.
2. Disconnect the wire of the faulty detector.
3. Remove the detector and replace it by a new one.
4. Connect the wire on the new detector.
5. Adjust the new detector at a distance from 2 or 3 mm compared to the part to detect
(the indicator of the detector lights).
6. Put back the frame.
04102011/GB
19.2013
Longitudinal folding: PLIVIT
(electricity, steam, water, gas, compressed air...).
32