Mitsubishi Electric MELSEC iQ-R Series User Manual page 164

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
SW0069
Installation
status
SW006D
Maximum link
scan time
SW006E
Current link
scan time
SW006F
Minimum link
scan time
SW0070
Total number of
stations
SW0071
Maximum
communication
station number
SW0072
Number of
connected
modules
SW0073
Standby master
station number
SW0074
Reserved
to
station
SW0077
specification
status
SW0078
Error invalid
to
station
SW007B
specification
status
APPX
162
Appendix 5 List of Link Special Register (SW) Areas
Description
Stores whether unique station numbers have been assigned for modules and
whether parameter settings match with connected module status.
0: Normal
Values other than 0:Error code ( Page 123 List of Error Codes)
Error details are stored in SW0098 to SW009B and SW009C to SW009F.
This item is checked, and the result is stored only at link startup.
Stores the maximum link scan time.
(unit: 1ms)
Stores the current link scan time.
(unit: 1ms)
Stores the minimum link scan time.
(unit: 1ms)
Stores the end station number set using the parameter.
1 to 64 (station)
Stores the maximum station number during data link (station number set using
the station number setting switches).
1 to 64 (station)
Reserved stations are excepted.
Stores the number of modules performing data link.
Reserved stations are excepted.
Stores the standby master station number.
1 to 64 (station)
Stores whether a station has been set as a reserved station.
0: A station other than a reserved station
1: Reserved station
b15
b14
b13
SW0074
16
15
14
SW0075
32
31
30
SW0076
48
47
46
SW0077
64
63
62
Only the bit corresponding to the start station number turns on.
The station with the end station number and stations later than that are excepted.
Stores whether a station has been set as an error invalid station.
0: A station other than an error invalid station
1: Error invalid station
b15
b14
b13
SW0078
16
15
14
SW0079
32
31
30
SW007A
48
47
46
SW007B
64
63
62
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
b12
to
b3
b2
b1
13
to
4
3
2
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
b12
to
b3
b2
b1
13
to
4
3
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
Availability (: Available, : Not
available)
Online
Master
Local
station
station
b0
1
17
33
49
b0
2
1
17
33
49
Offline