■Status of a remote device station, intelligent device station, local station, and standby master
station (when operating as a local station)
Data link status
When the CPU module of the master
station is set to STOP at an error ("Data
Link Setting at CPU Failure" =
"Continue the Data Link")
When the CPU module of the local
station is set to STOP at an error
When data link
"Input Data
for the entire
from Data
system is
Link Faulty
stopped
Station" (for
master
station
setting)
When a
"Input Data
communication
from Data
failure (such as
Link Faulty
power off)
Station" (for
occurs in a
master
remote I/O
station
station
setting)
When a
"Input Data
communication
from Data
failure (such as
Link Faulty
Station" (for
power off)
occurs in a
master
remote device
station
station
setting)
When a
"Input Data
communication
from Data
failure (such as
Link Faulty
power off)
Station" (for
occurs in a
master
local station
station
setting)
*1 If parameter settings have been configured using dedicated instructions, the data is held. If parameter settings have been configured
using an engineering tool, the data is cleared when Y is set to the refresh device of the remote output (RY). The data is held or cleared
according to "Output Mode upon CPU STOP" when the device other than Y is set.
*2 When Y is set to the refresh device of the remote output (RY) in the local station that has stopped, only the remote output (RY) in the
stopped local station is cleared. The data is held or cleared according to "Output Mode upon CPU STOP" when the device other than Y
is set. Data link is continued for the other local stations.
1 FUNCTIONS
36
1.1 Cyclic Transmission
Remote device station, intelligent device
station
Remote
Remote
input
output
(RX)
(RY)
*1
Continue
Continue
Continue
Clear
By
All points
external
off
signals
Hold
Clear
Continue
Continue
Hold
Clear
By
All points
external
off
signals
Hold
Clear
Continue
Continue
Hold
Local station, standby master station (operating as
a local station)
Remote
Remote
Remote
register
register
input
(RWw)
(RWr)
(RX)
Continue
Continue
Clear
Continue
Continue
Continue
Hold
By
Clear
external
signals
Hold
Continue
Continue
Continue
Hold
By
Continue
external
signals
Continue
Continue
Continue
Remote
Remote
output (RY)
register
(RWw)
Continue
Continue
*2
Continue
Clears the
Holds the receive
receive areas
areas from other
from other
stations.
stations.
Holds the receive
areas from other
stations.
Clears the
Continue
receive area from
the remote I/O
station having a
communication
failure.
Holds the receive
area from the
remote I/O
station having a
communication
failure.
Clears the
Holds the receive
receive area from
area from the
the remote
remote device
device station
station having a
having a
communication
communication
failure.
failure.
Holds the receive
area from the
remote device
station having a
communication
failure.
Clears the
Holds the receive
receive area from
area from the
the local station
local station
having a
having a
communication
communication
failure.
failure.
Holds the receive
area from the
local station
having a
communication
failure.
Remote
register
(RWr)
Continue
Continue
Hold
Continue
Continue
Continue