Optional Brake Chopper And Resistor(S) - ABB ACS800-U7 Hardware Manual

Acs800 45 to 560 kw; 50 to 600 hp
Hide thumbs Also See for ACS800-U7:
Table of Contents

Advertisement

142
• the resistance does not restrict the braking capacity needed, that is,,
where
P
U
R
• the heat dissipation capacity (E
above).

Optional brake chopper and resistor(s)

The nominal ratings for dimensioning the brake resistors for the ACS800-07/U7 are
given below at an ambient temperature of 40 °C (104 °F).
ACS800-07/U7
Frame
type
size
400 V units
-0075-3
R5
-0100-3
R6
-0120-3
R6
-0135-3
R6
-0165-3
R6
-0205-3
R6
-0260-3
R8
-0320-3
R8
-0400-3
R8
-0440-3
R8
-0490-3
R8
500 V units
-0105-5*
R5
-0120-5
R6
-0140-5
R6
-0165-5
R6
-0205-5
R6
-0255-5*
R6
-0270-5**
R8
-0300-5**
R8
-0320-5
R8
-0400-5
R8
-0440-5
R8
-0490-5
R8
-0550-5
R8
-0610-5
R8
Resistor braking
2
U
DC
P
max <
R
maximum power generated by the motor during braking
max
voltage over the resistor during braking, eg,
DC
1.35 · 1.2 · 415 VDC (when supply voltage is 380 to 415 VAC),
1.35 · 1.2 · 500 VDC. (when supply voltage is 440 to 500 VAC) or
1.35 · 1.2 · 690 VDC (when supply voltage is 525 to 690 VAC).
resistor resistance (ohm)
Braking power of the chopper and
the drive
5/60 s
10/60 s
30/60 s
P
P
P
br5
br10
br30
(kW)
(kW)
(kW)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240
240
240
300
300
300
375
375
273
473
355
237
500
355
237
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240
240
240
280
280
280
300
300
300
375
375
375
473
473
450
480
480
470
4)
600
400
300
3)
4)
600
400
300
) is sufficient for the application (see step 3
R
Brake resistor(s)
Type
P
brcont
(kW)
70
SAFUR80F500
83
SAFUR125F500
113
SAFUR125F500
132
SAFUR200F500
132
SAFUR200F500
160
SAFUR200F500
173
2XSAFUR210F575
143
2xSAFUR200F500
130
4xSAFUR125F500
120
4xSAFUR210F575
120
4xSAFUR210F575
83
SAFUR80F500
113
SAFUR125F500
135
SAFUR125F500
160
SAFUR125F500
160
SAFUR125F500
200
SAFUR200F500
240
2xSAFUR125F500
280
2xSAFUR125F500
300
2xSAFUR125F500
234
2XSAFUR210F575
195
2xSAFUR200F500
210
2xSAFUR200F500
170
4xSAFUR125F500
170
4xSAFUR125F500
R
E
P
R
Rcont
(ohm)
(kJ)
(kW)
6
2400
6
4
3600
9
4
3600
9
2.70
5400
13.5
2.70
5400
13.5
2.70
5400
13.5
1.70
8400
21
1.35
10800
27
1.00
14400
36
0.85
16800
42
0.85
16800
42
6
2400
6
4
3600
9
4
3600
9
4
3600
9
4
3600
9
2.7
5400
13.5
2.00
7200
18
2.00
7200
18
2.00
7200
18
1.70
8400
21
1.35
10800
27
1.35
10800
27
1.00
14400
36
1.00
14400
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-07

Table of Contents