K3I110 LON I/O p.c.b.

53
K3I110 LON I/O p.c.b.
53.1
Overview
53.2
Application
53.3
Key data
53.4
Wiring principle
LON-Bus
E3I040
24VDC
16 programmable monitored control inputs
226
Building Technologies
Fire Safety & Security Products
In-/output card with 16 programmable control in-/outputs
LON-Bus device
Max. 32 devices
Selectable ground fault monitoring, detected via master module E3X10. (for ap-
plication details –> see chapter 6)
Card format 100 mm x 200 mm
Equipped with mounting plate
The card communicate (LON-Bus) via converter module E3I040 (LON-/I-Bus)
with the control unit.
Output contacts, NO
Ratings relay contacts
Inputs
Operating voltage
Current consumption
* All relay activated incl. service LED
K1
K3I110
X31
X38
X56
16 programmable control outputs
Outputs are galvanically isolated, not supervised on open circuit,
short circuit or ground fault
Max. 1 A / 30 V
DC
supervised on open circuit, short circuit, deviation and ground fault
9..45 V
DC
24 V
min. 24 mA / max. 184 mA *
9 V
min. 53 mA / max. 218 mA *
45 V
min. 19 mA / max. 171 mA *
per activated relay (at 24 V) 10mA (without LED 9.2 mA)
per input with closed contact max. 0.5 mA
max. length of LON-Bus 1000 m
X63
24VDC
max. 30V /1A
K3I050
B3Q580
Data bus