E3M110 Line module "AnalogPLUS" (superseded by E3M111)

23
E3M110 Line module "AnalogPLUS"
23.1
Overview
23.2
Key data
23.3
Special functions
98
Building Technologies
Fire Safety & Security Products
E3M110 ≤ Index 'CE' is only compatible with EP3 and EP3a
E3M110 ≥ Index 'CE' is fully compatible with EP3, EP3a, EP4; (further details refer to MI221)
Line module for AnalogPLUS detectors
I-Bus module with line processor and independent emergency operation proces-
sor
Designed for 4 loop lines or stub lines
Line inputs protected against over voltage
Card format 100 mm x 200 mm
I-Bus address is set at programming switch "S3"
Addresses per line
Number of wires
Twisted cable
Line resistance
Line capacitance
Short-circuit proof line
T-branch
Quiescent current at 24 V
1) Limitations –> see document 001508
Terminal block X10 (20 terminals)
mounted on module chassis
for the connection of the prefabricated cable to connection level, or
for direct connection of the periphery
Card chassis
mounted on module chassis
Line separator
Upon short circuit the part of the line which malfunctions must be separated from
the rest of the line. This is carried out by line separators integrated in each detec-
tor, manual call point and input/output module. According to EN54, a "simple error"
may not cause the malfunction of more than 32 detectors. After the short circuit the
line automatically reverts to "Normal operating condition".
...128 1)
2
recommended
...150 Ω with 128 detectors 1)
...300 nF 1)
yes (autom. detectors, manual call points, input/output modules with
line separator)
yes (using DC1135)
210 mA with 512 detectors
(50 mA without detectors + 0.31 mA per D-Bus user)
(superseded by E3M111)
001260_k_en_--.doc
02.2005