Frame Size R4; Frame Sizes R5…R8 - ABB ACH580 Series Installation, Operation And Maintenance Manual

Hide thumbs Also See for ACH580 Series:
Table of Contents

Advertisement

ACH580 Installation, Operation and Maintenance Manual
R1...R2
2a
R3
2a

Frame Size R4

To replace the fan:
1. Remove power from drive.
2. Pry the fan assembly off the drive frame with a screwdriver
and pull it out.
3. Disconnect the fan cable.
4. Install the fan in reverse order.
5. Restore power.
Frame Sizes R5...R8
To replace the fan:
1. Remove power from drive.
2. Remove the 2 screws attaching the fan mounting plate at
the bottom of the drive.
3. Pull the mounting plate down from the side edge.
4. Disconnect the fan cable.
5. Lift the mounting plate off.
6. Remove the fan from the mounting plate.
7. Install the fan in reverse order.
8. Restore power.
2b
2b
2b
2b
83
3
3
4
3
2
ACH580-01 Installation