Optional Vm8000 Inmail Start-Up Programming; Set Up Automated Attendant To Answer Outside Calls - NEC Univerge SV8100 VM8000 InMail System Manual

Table of Contents

Advertisement

VM8000
2.2
2.3
InMail System Guide
7.
For extensions 101~108, the Subscriber Mailbox numbers are the same
as the extension numbers.
47-02-02
VM8000 InMail Station Mailbox Options – Mailbox Number
Normally, Subscriber Mailbox numbers correspond to the respective
extension number. (For example, extensions 101~126 should use
Subscriber Mailbox numbers 101~126).
Options
1~256
Default
Not Assigned
8.
Also, the following program must be configured in a default system.
15-03-03
Single Line Telephone Basic Data Setup – Terminal Type
Set at 1 (Special) for VM8000 InMail extensions.

Optional VM8000 InMail Start-Up Programming

Program Voice Mail keys on system extensions.
15-07-01
Programming Function Keys
Voice Mail keys are code 77.
Normally, the additional data is the number of the extension you are
programming.
You can optionally set up an extension Message key for Voice Mail
access in the next step.
Keysets can also have Voice Mail keys for Virtual Extensions, a
co-worker, or an uninstalled extension (for Message Center
operation).
Extension users can use Service Code 751 to set up their own Voice
Mail keys.
By default, no Voice Mail keys are assigned.


Set up Automated Attendant to Answer Outside Calls

To have Automated Attendant answer outside calls, perform the following:
Set up Direct Inward Lines (DILs)
H
Terminate DILs to VM8000 InMail
H
After the DILs to VM8000 InMail are set up, all calls are answered by Call
H
Routing Mailbox 1 and Dial Action Table 1.
Answer Table 1 Runs Monday-Friday from 8:30AM to 5:00PM, and uses
H
Call Routing Mailbox 1.
Issue 1.0