ROP.Setup.software.
(continued)
CAMERA.NO.(5)
Displays the camera numbers.
<NOTE>
In serial connection mode, only the camera number configured in
[CAMERA NUMBER(SERIAL)](4) can be connected.
CAMERA.TYPE.(SERIAL).(6)
Displays the connection types.
<NOTE>
In serial connection mode, the device selected for CAMERA TYPE
(Serial) (3) is displayed.
CAMERA.MODEL.(7)
Clicking the [REFRESH] button (13) displays the connected
devices.
<NOTE>
With serial connection, model information is displayed only when a
remote camera is selected.
REFRESH.button.(13)
Acquires connection information set to the unit on the personal
computer and updates the [Camera List] tab display.
z With.the.IP.connection.mode
.
4 3
5
6
7
8
9
CONNECTION.MODE.(2)
Set the connection mode of the selected ROP.
To select the IP connection mode, select the [IP Mode] button
Serial Mode:
Make serial mode connection settings.
IP Mode :
Make IP connection mode settings.
CAMERA.TYPE.(SERIAL).(3)
Set the devices to be connected by serial connection. Select the
connection devices.
CCU :
Serial connection is used with the CCU.
Remote Camera:
Serial connection is used with the remote camera.
Camcoder:
Serial connection is used with the camera recorder.
<NOTE>
With IP connection, serial connection is possible only for the device
selected at CAMERA TYPE (SERIAL) (3).
CAMERA.NUMBER.(SERIAL).(4)
These settings are not possible in IP connection mode.
CAMERA.NO.(5)
Displays the camera numbers.
Settings from [C01] to [C19] are possible.
CAMERA.TYPE.(SERIAL).(6)
Click
and select the connection type from among [CCU Serial],
[CCU IP], [Remote Serial], [Remote IP], [Camcoder IP], [Camcoder
Serial] or [No Asign].
CCU Serial:
Serial connection with CCU.
CCU IP :
IP connection with CCU.
Remote Serial:
Serial connection with remote camera
Remote IP:
IP connection with remote camera
Camcoder IP:
IP connection with camera recorder
Camcoder Serial:
Serial connection with camera recorder
NoAsign:
Not set (default setting)
CAMERA.MODEL.(7)
The [NETWORK SEARCH] button (12) displays acquired device
connections.
<NOTE>
Serially connected remote cameras are displayed, but serially
connected CCUs are not displayed.
MAC.ADDRESS.(8)
Displays the MAC addresses of cameras linked with camera
numbers [CAMERA NO] (5) on the unit.
MAC addresses of devices corresponding to camera numbers
acquired by the [NETWORK SEARCH] button (12) are displayed.
IP.ADDRESS.(9)
Set the IP addresses of the cameras being connected.
After input, click the [SET] button (14) to reflect the changes.
2
CAMERA.PORT.NO.(10)
Set the port numbers of cameras being connected.
After input, click the [SET] button (14) to reflect the changes.
Possible setting
range:
*
1
However, the following values cannot be set even though they
are within this range.
20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162, 995,
10669, and 10670
<NOTE>.
Ordinarily, the settings are made as follows. However, if any of the
settings have been changed on the camera side, the settings made
here must match those changes.
CCU IP:
Remote IP:
Camcoder IP:
SWAP.CAMERA.(11)
Swap the camera connections set between two camera numbers.
Click
to display camera numbers [C01] to [C19].
Select the camera number with which you want to make the swap
from this list.
After making a change, click the [SET] button (14) to reflect it.
NETWORK.SEARCH.button.(12)
When you click the [NETWORK SEARCH] button, link settings
corresponding to the cameras (CAMERA NO) newly detected by the
10
unit are displayed in yellow.
11
If you click the [SET] button (14), the settings are confirmed and the
IP addresses connected to the unit are updated.
If you click the [CANCEL] button (16), the settings are not reflected.
<NOTE>.
• Camera recorders cannot be detected. If no camera recorder
was detected by executing NETWORK SEARCH, click the [SET]
button once and then set the camera recorder manually. Then
.
click the [SET] button again and confirm the setting.
• If a duplication error occurred during NETWORK SEARCH,
change the IP addresses on the screen. A duplication error is
displayed if the IP addresses of two or more cameras displayed
on the screen are duplicates, or if the IP addresses of a camera
displayed on the screen and a camera you are attempting newly
add to the network are duplicates. Change the IP addresses for
which the error was displayed, register the cameras to the unit,
and then execute NETWORK SEARCH.
REFRESH.button.(13)
Acquires connection information set to the unit on the personal
computer and updates the [Camera List] tab display.
SET.button.(14)
Confirm the changes on the [Camera List] tab and update the
settings on the unit.
When the [Do you agree to rebooting after data transfer?] message
appears, click the [OK] button. If you click [CANCEL], the settings
are not reflected on the unit.
CANCEL.button.(15)
Cancels changes that were made after executing NETWORK
SEARCH (12).
INITIALIZE.(FACTORY.SETUP).button.(16).
Click the [INITIALIZE] button to initialize the unit settings. (This is
equivalent to "Initialize settings" of setup menu number 16 of the
unit.)
The IP address is also initialized (factory default setting:
192.168.0.130). If a unit with other than the factory default setting
(192.168.0.130) is selected, change the IP setting with Easy IP
Setup Software. (→page 34)
When the [Do you agree to rebooting after data transfer?] message
appears, click the [OK] button. The unit restarts and the configured
settings are reflected. If you click [CANCEL], the settings are not
reflected on the unit.
1 to 65535
*
1
80
80
49152
37