Setup.mode.
(continued)
„ Opening.setup.mode
Setup mode differs from normal operating modes. Use the steps below
to open setup mode.
1..
When.a.camera.and.CCU.are.connected,.select.IRIS.(to.
light.the.<IRIS>.display.on.the.panel).
If the IRIS display is not lit, press the selected <DISPLAY SELECT>
button to select IRIS.
UP
ND
CC
M.GAIN
DATA
SET
IRIS
DOWN
DISPLAY SELECT
SET UP
ND/CC M.GAIN/M.PED SHUTTER
SHIFT
+
SAVE/LOAD
EXIT
UP+DOWN
IRIS display
Use the steps below to open setup mode when the power is on, but a
camera or CCU is not connected.
2..
Simultaneously.hold.down.DATA.SET.<DATA.SET>.
<UP>,.<DOWN>.and.<SHIFT>.for.approximately.two.
seconds.
This opens setup mode and Menu No. 1 (camera number setting) is
displayed.
SCENE/USER FILE
SHIFT
SCENE 1
SCENE 2
USER 1
USER 2
UP
ND
CC
M.GAIN
DATA
SET
IRIS
DOWN
DISPLAY SELECT
ND/CC M.GAIN/M.PED SHUTTER
SET UP
SHIFT
+
SAVE/LOAD
EXIT
UP+DOWN
CAMERA
SHT
SYNC
M.PED
10-19
No.
SELECT
EXECUTE
SCENE 3
SCENE 4
STORE
USER 3
CAMERA
SHT
SYNC
M.PED
10-19
No.
SELECT
EXECUTE
„ Exiting.setup.mode
To exit setup mode, hold down <EXIT> for two seconds. The unit returns
to normal operating mode.
UP
ND
CC
M.GAIN
DATA
SET
IRIS
DOWN
DISPLAY SELECT
SET UP
ND/CC M.GAIN/M.PED SHUTTER
SHIFT
+
UP+DOWN
SAVE/LOAD
EXIT
„ Basic.operations
The buttons indicated in the figure below are available in setup mode.
No other buttons are available. All other LEDs stay off. (Except the
alarm display)
1
2
UP
ND
CC
M.GAIN
DATA
SET
IRIS
DOWN
DISPLAY SELECT
SET UP
ND/CC M.GAIN/M.PED SHUTTER
SHIFT
+
SAVE/LOAD
EXIT
UP+DOWN
7
8
1..
Selects.set.values
2..
Indicates.selected.submenu
3..
Indicates.set.values.and.selected.values
4..
Indicates.menu.numbers
5..
Selects.a.menu.number..Each.press.of.the.button.
increments.menu.numbers.
1→2→3→...→21→1→2→...
6..
Confirms.a.setting
7..
Selects.a.submenu..Each.press.of.the.button.opens.a.
different.submenu.
8..
To.exit.setup.mode,.hold.down.<EXIT>.for.two.seconds..
The.unit.returns.to.normal.operating.mode.
UP
ND
CC
M.GAIN
DATA
SET
IRIS
DOWN
DISPLAY SELECT
SET UP
ND/CC M.GAIN/M.PED SHUTTER
SHIFT
+
SAVE/LOAD
EXIT
UP+DOWN
SHT
SYNC
CAMERA
M.PED
10-19
No.
SELECT
EXECUTE
3
4
CAMERA
SHT
SYNC
M.PED
10-19
No.
SELECT
EXECUTE
6
5
CAMERA
SHT
SYNC
M.PED
10-19
No.
SELECT
EXECUTE
7