Product Identification; Name Plate; Transport; Inspection - ABB PositionMaster EDP300 Commissioning Instruction

Digital positioner
Hide thumbs Also See for PositionMaster EDP300:
Table of Contents

Advertisement

4

Product identification

4.1

Name plate

1
2
3
4
5
6
7
ABB Automation
8
Schillerstrasse 72
D - 32425 Minden
Made in Germany
Fig. 1:
Name plate (example)
1 Full type designation 2 Order code 3 Serial number 4 Special version 5 Hardware revision / Software revision
6 Date of manufacture 7 Explosion protection 8 Manufacturer 9 Supply pressure j Input signal k Ambient temperature range
l Output m Safety function powered off n Communications protocol o IP rating p Options
NOTICE
The name plates displayed are examples. The device identification plates affixed to the device can differ from this
representation.
Change from one to two columns
5

Transport

5.1

Inspection

Check the devices immediately after unpacking for possible
damage that may have occurred from improper transport.
Details of any damage that has occurred in transit must be
recorded on the transport documents.
All claims for damages must be submitted to the shipper
without delay and before installation.
Supply press: 0,14 ... 1 MP a
Input: analog 4 - 20 mA
Ambient temperature: -40°C ... 85°C
Output: double acting
Loss of electr. Supply: fall safe
H
IP65
HART
Options:
Analog feedback output
Digital feedback output
Universal analog input
Safety shut down
Pressure sensors
Electr. limit switch
Mech. limit switch, low
Mech. limit switch, high
Contactless pos. Sensor
5.2

Returning devices

Use the original packaging or a secure transport container of
an appropriate type if you need to return the device for repair
or recalibration purposes.
Include the return form once it has been properly filled out (see
appendix in operating instructions) with the device.
According to the EU Directive governing hazardous materials,
the owner of hazardous waste is responsible for its disposal or
must observe the following regulations for shipping purposes:
All devices delivered to ABB must be free from any hazardous
materials (acids, alkalis, solvents, etc.).
Please contact Customer Center Service acc. to page 2 for
nearest service location.
PositionMaster EDP300 | CI/EDP300-EN Rev. C 11
9
j
k
l
m
n
o
Slot1
Slot2
p
X
X
X
M10154-01

Advertisement

Table of Contents
loading

Table of Contents